Evidence Summary Table

about 2 minutes

ClaimValueSourceGrade
Electromechanical delay (voluntary)49.73 ± 6.99 msBegovic et al. 2014, Front. Physiol.A
Optimal myoelectric controller delay100 ms (fast) / 125 ms (slow)Farrell & Weir 2007, IEEE TNSREA
Electrode shift, 2 cm−7.6% to −20%Tanaka et al. 2025, Sensors (consolidating)A/B
Re-donning shift magnitude1.16 ± 0.34 cmHwang et al. 2017, PLOS ONEA
Limb-position effect3.8% → 18% errorFougner et al. 2011, IEEE TNSREA
Cross-session degradation~10–12 ppRehman et al. 2018, SensorsA
Skin impedance stabilisation~15 minSousa et al. 2023, SensorsA
Cross-user hand-pose error (best)12.2°emg2pose, NeurIPS 2024A
Generic sEMG, no calibration>90% held-out-user; 11,236 participantsKaifosh et al. 2025, Nature 645A
EMG vs conventional interfaces26% slower, 58× error, 2.8× TLXM4Bench 2025, Front. Robot. AIA
Tele-impedance vs constant stiffness83.3% vs 78.3% / 60.0%Fani et al. 2018, IEEE RAMA
Tele-impedance under 1 s delay12.33 N vs 24.31 N peak forceLaghi et al. 2020, IJRRA
Vision-derived stiffness (no EMG)0.87 vs 0.76 / 0.24 success; TLX 38.7 vs 49.3 / 52.4Stiffness Copilot 2026C
EMG force annotation → policy87% pick–squeeze–place; 0/10 baseline squeezeForceBand 2026C
Force relabelling of actionsnear-zero → 76%DexForce, RA-LA
Force as raw observation0.475–0.575 vs 0.500 baseline (≈ nil)FoAR, RA-LA
Gated force fusion0.875 vs 0.500FoAR, RA-LA
Tactile can hurt0.95 → 0.80 (Daimon, pick-and-place)TaCo 2026C
Hallucinated tactile ≈ real45% vs 35% (cup nesting)FELT 2026C
VLA new-task adaptation10–150 demosOpenVLA, CoRL 2024A
LoRA vs full fine-tune68.2% vs 69.7%; 1.4% params; 8× computeOpenVLA, CoRL 2024A
VLA new-embodiment adaptation<200 examplesGemini Robotics On-Device 2D
Curation with influence functionsSOTA at <33% of dataCUPID, CoRL 2025A
Curation with smoothness (SPARC)+16% at 1/6 dataRINSE 2026C
Mixed-operator penalty72% → 42% (Transport)robomimic, CoRL 2021A
Policy noise at low data69.7% vs 48.3% (50 eps)Belkhale et al., NeurIPS 2023A
Prosthesis as data-collection hand79.3% over 450 trialsHannesImitation 2025C
Shared autonomy, HD-EMG, in home738 s → 517 ± 62 s (−30.0%)Yang et al. 2026C
Shared autonomy cognitive load0.62 s vs 0.74 s DRT (−24%)George lab, Nat. Commun. 2025A